HomeGuideProcesses— Hot Rolling Mills— Cold Rolling Mills— TMT Bar ProcessProducts— I-Beams— H-Beams— Channels— Angles— TMT RebarToolsContact

ISMB 450

Indian Standard Medium Weight Beam per IS 808 : 1989 — depth 450mm, flange width 150mm, web thickness 9.4mm, flange thickness 17.4mm, weight 72.4 kg/m.

IS 808 : 1989·Hot Rolled·72.4 kg/m

Cross Section

Y Y Z Z d = 450 b = 150 tw = 9.4 tf = 17.4 R1 = 15.0 R2 = 7.5 Flange slope 98° · All dimensions in mm ISMB 450 IS 808 : 1989 — Cross Section
Proportionally accurate · True R1 & R2 radii · IS 808 : 1989
Download PDF Spec Sheet Chat on WhatsApp

Key Dimensions

450mm
Depth (d)
150mm
Flange Width (b)
9.4mm
Web (tw)
17.4mm
Flange (tf)
15.0mm
Root Radius (R1)
7.5mm
Toe Radius (R2)
72.4kg/m
Weight
9230mm2
Area

Sectional Properties

PropertyAbout X-X AxisAbout Y-Y Axis
Moment of Inertia (I)303,910,000 mm⁴ (30391.0 cm⁴)8,340,000 mm⁴ (834.0 cm⁴)
Elastic Section Modulus (Z)1,350,700 mm³ (1350.7 cm³)111,200 mm³ (111.2 cm³)
Plastic Section Modulus (Zp)1,573,000 mm³ (1573.0 cm³)176,300 mm³ (176.3 cm³)
Radius of Gyration (r)181.5 mm30.1 mm
Distance to Extreme Fibre (c)225.0 mm (d/2)75.0 mm (b/2)
Shape Factor (Zp/Z)1.1651.585
Torsional Constant (It)510,000 mm⁴ (51.0 cm⁴)
Warping Constant (Iw)442,000,000,000 mm⁶
Polar Moment (Ip = Ix + Iy)312,250,000 mm⁴ (31225.0 cm⁴)

Surface & Geometric Properties

Useful for paint estimation, fire protection coating quantities, and section analysis:

1.57m²/m
Surface Area
1570mm
Section Perimeter
4230mm²
Shear Area (Av)
21.7m²/t
Surface / Mass

Surface area calculated from full cross-section perimeter including flange tips. Shear area Av = d × tw per IS 800 : 2007 cl. 8.4. Surface/mass ratio used for estimating paint and fireproofing coverage per kg of steel.

Allowable Loads (Factored)

Calculated per IS 800 : 2007 (limit state design) using partial safety factor γm0 = 1.10. Values assume the section is fully laterally restrained. Reduce for unsupported lengths per IS 800 cl. 8.2.

GradePlastic Moment Mp (X-X)Plastic Moment Mp (Y-Y)Axial Capacity (Short)
E 250357.5 kN·m40.1 kN·m2098 kN
E 350500.5 kN·m56.1 kN·m2937 kN
E 410586.3 kN·m65.7 kN·m3440 kN
E 450643.5 kN·m72.1 kN·m3776 kN

Mp = Zp × fy / γm0. Axial capacity = A × fy / γm0 for short, fully-restrained columns. For longer columns, apply slenderness reduction per IS 800 cl. 7.1.2.

International Equivalents

StandardEquivalent SectionDepthWeight
India (IS 808)ISMB 450450 mm72.4 kg/m
Europe (EN)IPE 450
UK (BS)457×152×52 UB
USA (ASTM)W18×50
Japan (JIS)H 450×175
Germany (DIN)I 450

Equivalence based on closest matching depth and weight. Note that ISMB has tapered flanges (8° slope per IS 808) while IPE, UB, and W-shapes have parallel flanges. Always verify exact properties from the actual standard before substituting in design calculations.

Available Grades (IS 2062 : 2011)

GradeYield (MPa)UTS (MPa)Elong.Application
E250 (Fe 410W)25041023%General construction
E275 (Fe 440)27544022%Commercial buildings
E30030044022%Industrial structures
E350 (Fe 490)35049022%Heavy industrial, bridges
E410 (Fe 540)41054020%Heavy structural, offshore
E450 (Fe 570)45057020%Bridges, towers

Applicable Standards

← Previous
ISMB 400
Next →
ISMB 500
×