ISHB 200

Indian Standard Heavy Beam per IS 808 : 1989 — depth 200mm, flange width 200mm, web thickness 7.8mm, flange thickness 9.0mm, weight 37.3 kg/m. Wide-flange section optimised for columns and compression members.

IS 808 : 1989·Hot Rolled·37.3 kg/m·Light variant

Cross Section

Y Y Z Z d = 200 b = 200 tw = 7.8 tf = 9.0 R1 = 9.0 Parallel flange · All dimensions in mm ISHB 200 IS 808 : 1989 — Cross Section
Parallel flange · True R1 root radius · IS 808 : 1989
Download PDF Spec Sheet Chat on WhatsApp

Key Dimensions

200mm
Depth (d)
200mm
Flange Width (b)
7.8mm
Web (tw)
9.0mm
Flange (tf)
9.0mm
Root Radius (R1)
37.3kg/m
Weight
4754mm²
Area
47.5cm²
Area (cm²)

Sectional Properties

PropertyAbout X-X AxisAbout Y-Y Axis
Moment of Inertia (I)34,635,000 mm⁴ (3463.5 cm⁴)12,004,000 mm⁴ (1200.4 cm⁴)
Elastic Section Modulus (Z)346,400 mm³ (346.4 cm³)120,000 mm³ (120.0 cm³)
Plastic Section Modulus (Zp)386,700 mm³ (386.7 cm³)182,800 mm³ (182.8 cm³)
Radius of Gyration (r)85.3 mm50.2 mm
Distance to Extreme Fibre (c)100.0 mm (d/2)100.0 mm (b/2)
Shape Factor (Zp/Z)1.1161.523
Torsional Constant (It)176,100 mm⁴ (17.6 cm⁴)
Warping Constant (Iw)110,210,000,000 mm⁶
Polar Moment (Ip = Ix + Iy)46,639,000 mm⁴ (4663.9 cm⁴)

Surface & Geometric Properties

Useful for paint estimation, fire protection coating quantities, and section analysis:

1.15m²/m
Surface Area
1149mm
Section Perimeter
1560mm²
Shear Area (Av)
30.8m²/t
Surface / Mass

Surface area calculated from full cross-section perimeter. Shear area Av = d × tw per IS 800:2007 cl. 8.4. Surface/mass ratio used for estimating paint and fireproofing coverage per kg of steel.

Allowable Loads (Factored)

Calculated per IS 800:2007 (limit state design) using partial safety factor γm0 = 1.10. Values assume the section is fully laterally restrained (short column / fully restrained beam). Reduce for slenderness and unsupported lengths per IS 800 cl. 7.1.2 and cl. 8.2.

GradePlastic Moment Mp (X-X)Plastic Moment Mp (Y-Y)Axial Capacity Pd (Short)
E 250 (Fe 410W)87.9 kN·m41.5 kN·m1080 kN
E 350123.0 kN·m58.2 kN·m1513 kN
E 410144.1 kN·m68.1 kN·m1772 kN
E 450158.2 kN·m74.8 kN·m1945 kN

Mp = Zp × fy / γm0. Axial capacity Pd = A × fy / γm0 for short, fully-restrained columns. For longer columns, apply slenderness reduction per IS 800 cl. 7.1.2.

International Equivalents

StandardEquivalent Section
India (IS 808)ISHB 200 @ 37.3 kg/m
Europe (EN) — HE-AHE 200 A
Europe (EN) — HE-BHE 180 B
UK (BS) — UC203×203×46 UC
USA (ASTM) — W-shapeW8×31

Equivalence based on closest matching depth and weight. ISHB has a slightly different flange-to-depth ratio than HE/UC/W-shapes. Always verify exact properties from the actual standard before substituting in design calculations.

Available Grades (IS 2062 : 2011)

GradeYield (MPa)UTS (MPa)ElongationApplication
E 250 (Fe 410W)25041023%General construction
E 35035049022%Multi-storey buildings
E 41041054020%Heavy columns, high-rise
E 45045057020%Bridges, offshore

Applicable Standards